Introduction

The latest INDION Swift range comprises a family of automatic twin-bed deionisers incorporating state-of-the-art counter-flow ion-exchange technology previously available only in much larger, custom-designed plant.

The operational cycle of these rapid-regeneration, packaged units is controlled by volume throughput, which is pre-programmed into the PLC according to the type of feed water. The ion exchange resins are never fully exhausted ensuring optimum deionized water production at all times.

Regeneration takes approximately 35 minutes - after a minimum service cycle of two hours -minimizing the need for both, standby plant and the storage of large volumes of water. As regeneration of the cation and anion beds is simultaneous, the effluent streams are largely self-neutralizing, reducing waste disposal costs and environmental impact.

The Swift is exceptionally compact, and is skid-mounted on a corrosion-resistant frame which also accommodates a stainless steel multi-purpose pump. In addition to optimising the performance of the plant during service and regeneration, the pump provides a number of re-circulation options to maintain the high quality of the water in the treated water tank.

Product Description

The INDION Swift  Plus features an additional cation exchange stage which is accommodated on the standard, compact skid. As a result the Swift plus produces mixed bed quality water having a resistivity of always greater than 1 mg.ohms-cm for a minimum capital outlay. Running cost are low because no additional regenerant chemicals are required and no extra effluent is produced.

The units are made  from FRP materials and hence last for long time. The cation and anion are packed bed units & regenerated by using Counter Current mode of regeneration . All the operations of plants are auto based on PLC. The regeneration of cation and anion is done at same time & hence the regeneration wastewater of the plant is neutral.

Features

Applications

General

Specific Industry

 

 

 

 

 

 